Featuring: CitroButter™ S, Citropol® V5, Citropol® H
A multifunctional cosmetic stick for enhancing ones’ natural features.
Phase
Trade Name
INCI
Supplier
%
B
Ricnius Communis (Castor) Seed Oil
38.47
Glycerin
9.05
Copernicia Cerifera (Carnauba) Wax
9.78
Euphorbia Cerifera (Candelilla) Wax
3.24
CitroButter™ S
Polycitronellol (and) Sunflower Seed Wax (and) Shea Butter
P2 Science
3.60
Glyceryl Behenate
4.07
Sodium Stearate
1.62
Stearic Acid
1.62
INBP45R7C
Red 21 Lake (and) Isononyl Isononoate (and) Isopropyl Myristate (and) Stearlakonium Hectorite (and) Isopropyl Titanium Triisostearate (and) Propylene Carbonate (and) Polyhydroxystearic Acid
k Products, Inc.
2.00
B
Citropol® V5
Polycitronellol Acetate (and) Undecane (and) Tridecane
P2 Science
15.22
Citropol® H
Polycitronellol
P2 Science
2.70
K-RAY® PERPETUAL SUMMIT RED
Titanium Dioxide (and) Mica (and) Silica
Kobo Products, Inc.
5.00
KTZ® VIBRANT GOLD
Mica (and) Titanium Dioxide (CI 77891) (and) Iron Oxides (CI 77491)
Kobo Products, Inc.
0.58
Maranta Arundinacea Root Extract
3.00
CI 77491 (and) Mica
Sensient Beauty
0.05
Procedure
- In a suitable beaker, add Castor Oil and Glycerin, while mixing and heating to 90ºC.
- Once at 90ºC, add the remaining Phase A ingredients. Mix well until all solids are melted.
- Cool to 70ºC.
- Add Phase B one item at a time, mixing well for 5 minutes after each addition.
- Begin cooling to 50ºC, then pour into mold. Refrigerate for 15 minutes.
- Put into suitable component and enjoy!

The information in this document is intended to demonstrate the possible technical applications and uses of P2 Science, Inc’s cosmetic ingredient(s) for informational purposes only. Any recommendations or suggestions are made without guarantee or warrantee in each country. This is not a license under any intellectual property right of any entity or a recommendation or authorization to action that infringes any intellectual property right. P2 Science, Inc shall not be held liable for any direct or indirect damages arising out of or in connection with the accuracy, completeness, adequacy, use, or reliance upon information provided herein. It is the customer’s responsibility to determine the full safety, suitability, and regulatory compliance for their own use of the product demonstrated herein.