Featuring: CitroButter™ S, Citropol® V6
A gel-like cream that hydrates the skin and prevents dryness for all-day wear.
Phase
Trade Name
INCI
Supplier
%
A
DI Water
Water
72.26
Glycerin, USP
Glycerin
5.00
Propanediol 1,3
Propanediol
2.00
Natrasol™ PLUS 330 CS
Cetyl Hydroxyethylcellulose
Ashland
1.14
B
Citropol® V6
Bis-Polycitronellyl Succinate (and) Undecane (and) C13-14 Alkane
P2 Science
8.00
CitroButter™ S
Polycitronellol (and) Sunflower Seed Wax (and) Shea Butter
P2 Science
3.00
MONTANOV™ 68 MB
Cetearyl Glucoside (and) Cetearyl Alcohol
Seppic
2.05
Glyceryl Stearate SE
Glyceryl Stearate SE
2.05
Triglyceride
Capric/Caprylic Triglyceride
1.55
C
Phenoxyethanol
Phenoxyethanol
0.70
Fision Hydrate Pro
Sodium PCA, Panthenol, Sodium Hyaluronate, L-Proline, Hydroxyproline
Tri-K Industries, Inc.
0.50
Caprylyl Glycol EHG
Caprlyl Glycol (and) Ethylhexylgylcerin
0.50
Radish Root Ferment Filtrate
Glycerin, Leuconstoc/radish root ferment filtrate, Lonicera Japonica flower extract, Lonicera Caprifolium flower extract, Populus Tremuloides extract, gluconolactone
0.50
Allantoin USP
Allantoin
Tri-K Industries, Inc.
0.25
D
Citric Acid 50% Solution
QS
Procedure
- In a suitable beaker, add Water. Begin mixing and heating to 75ºC.
- Premix the rest of Phase A, the n add to the main vessel. Mix for 30 minutes.
- In a separate beaker, combine Phase B. heat to 75ºC while mixing.
- Slowly add Phase B to Phase A under homogenization.
- Mix at high shear for 10 minutes.
- Begin cooling to room temperature.
- Once below 40ºC, add phase C, one item at a time. Mix well after each addition.
- Adjust pH to 4.5– 5 with 50% Citric Acid Solution.
- Pour into a suitable component and enjoy!

The information in this document is intended to demonstrate the possible technical applications and uses of P2 Science, Inc’s cosmetic ingredient(s) for informational purposes only. Any recommendations or suggestions are made without guarantee or warrantee in each country. This is not a license under any intellectual property right of any entity or a recommendation or authorization to action that infringes any intellectual property right. P2 Science, Inc shall not be held liable for any direct or indirect damages arising out of or in connection with the accuracy, completeness, adequacy, use, or reliance upon information provided herein. It is the customer’s responsibility to determine the full safety, suitability, and regulatory compliance for their own use of the product demonstrated herein.