Multizone Deo Lotion

Featuring: Citropol® DE-4, Citropol® F

A lightweight, whole-body deo lotion that hydrates and softens skin, and neutralizes odor with a warm, lasting fragrance.

Phase

Trade Name

INCI

Supplier

%

A

DI Water

Water

70.85

Aloe Vera 10x Concentrated

Aloe Barbadensis Leaf Juice

1.50

B

Glycerin, USP

Glycerin

3.00

Vanzan NF

Xanthan Gum

Vanderbilt Minerals, LLC

0.35

C

Olivem® 1000 MB

Cetearyl Olivate (and) Sorbitan Olivate

Hallstar

4.00

Citropol® DE-4

Bis-Polycitronellyl Succinate

P2 Science

3.00

Sunflower Oil

Helianthus Annuus (Sunflower) Seed Oil

From Nature With Love

2.00

Hallstar CO-1895 Stearyl Alcohol

Stearyl Alcohol

Hallstar

2.00

Zinc ricinoleate

Zinc ricinoleate

1.75

Myristyl Myristate

Myristyl Myristate

1.50

Shea Butter, USDA Certified Organic

Organic Butyrospermum Parkii (Shea) Butter

0.50

D

Corn Starch

Zea Mays (Corn) Starch

From Nature With Love

3.00

L(+)- Lactic Acid 90%

Lactic Acid

Jungbunzlauer

3.00

E

Citropol® F

Polycitronellol

P2 Science

2.00

Bum Bum Fragrance Oil 1255

Fragrance (Parfum)

0.30

F

Phenoxyethanol

Phenoxyethanol

0.70

Caprylyl Glycol EHG

Caprylyl Glycol (and) Ethylhexylglycerin

0.55

Procedure

  1. In primary beaker, add phase A.
  2. Combine phase B to form a slurry. Add phase B to phase A. Begin heating phase AB to 70ºC
  3. In separate beaker, combine phase C and heat to 70ºC.
  4. When both phases are homogenous and at temperature, slowly add phase C to phase AB.
  5. Begin cooling down to below 45ºC.
  6. Once temperature is below 45ºC, begin adding phase D one at a time.
  7. Make a premix with phase E ingredient and then add to primary beaker.
  8. Add F individually once phase E is completely mixed in.
  9. Adjust pH to be between 4.0-5.0

The information in this document is intended to demonstrate the possible technical applications and uses of P2 Science, Inc’s cosmetic ingredient(s) for informational purposes only. Any recommendations or suggestions are made without guarantee or warrantee in each country. This is not a license under any intellectual property right of any entity or a recommendation or authorization to action that infringes any intellectual property right. P2 Science, Inc shall not be held liable for any direct or indirect damages arising out of or in connection with the accuracy, completeness, adequacy, use, or reliance upon information provided herein. It is the customer’s responsibility to determine the full safety, suitability, and regulatory compliance for their own use of the product demonstrated herein.