Velvet Infusion Body Cream

Featuring: Citropol® DE-4, Citropol® F

A luxurious, buttery lotion that leaves the skin feeling deeply nourished and hydrated.

Phase

Trade Name

INCI

Supplier

%

A

DI Water

Water

67.15

Tetrasodium Glutamate Diacetate

Essential Labs

0.20

B

Glycerin

2.00

Propanediol 1,3

1.00

Xanthan Gum

0.20

C

Caprylic/Capric Triglyceride

10.00

Prunus Armeniaca (Apricot) Kernel Oil

0.50

Glyceryl Stearate Citrate

3.00

Cetearyl Alcohol

3.00

Cocoa Butter Deodorized, USDA Certified Organic

Organic Theobroma cacao (cocoa butter)

0.50

Citropol® DE-4

Bis-Polycitronellyl Succinate

P2 Science

5.00

Parafol 12

Dodecane

Sasol

5.00

D

Vitamin E, Mixed Tocopherols 95%

Tocopherol

LotionCrafter

0.20

Phenoxyethanol

0.70

Caprylyl Glycol EHG

Caprylyl Glycol (and) Ethylhexylglycerin

0.55

E

Cashmere Cream Fragrance Oil 682

Fragrance

Crafter’s Choice

0.50

Citropol® F

Polycitronellol

P2 Science

0.50

F

pH Adjuster

Q.S.

Procedure

  1. In a suitable beaker, add phase A and begin mixing while heating to 80°C.
  2. Premix phase B to form a slurry, then add directly to phase A.
  3. In a separate beaker, combine phase C and heat to 80°C until fully melted and homogenous.
  4. When phase AB and phase C are both at temperature, add phase C.
  5. Homogenize for 5 minutes under high shear.
  6. Cool sample (naturally) while mixing.
  7. Add phase D when sample is below 40°C, one at a time and ensure full incorporation of each addition.
  8. Premix phase E before adding to main beaker.
  9. Adjust pH to be 5.0 ± 0.5 using Citric Acid and NaOH solution.

The information in this document is intended to demonstrate the possible technical applications and uses of P2 Science, Inc’s cosmetic ingredient(s) for informational purposes only. Any recommendations or suggestions are made without guarantee or warrantee in each country. This is not a license under any intellectual property right of any entity or a recommendation or authorization to action that infringes any intellectual property right. P2 Science, Inc shall not be held liable for any direct or indirect damages arising out of or in connection with the accuracy, completeness, adequacy, use, or reliance upon information provided herein. It is the customer’s responsibility to determine the full safety, suitability, and regulatory compliance for their own use of the product demonstrated herein.