Featuring: Citropol® H
A facial serum that enhances vitamin C while restoring skin and adding hydration.
Phase
Trade Name
INCI
Supplier
%
A
DI Water
69.28
Aloe Barbadensis
2.000.75
Glycerin USP
20.00
Hyaluronic Acid
0.01
Hydroxyethylcellulose
1.00
B
DI Water
15.00
Sodium Ascorbyl Phosphate
0.50
Magnesium Ascorbyl Phosphate
0.50
Glycerin (and) Water (and) Apple (Pyrus Malus) Fruit Extract
0.50
Glycerin (and) Water (and) Morus Alba (Mulberry) Root Extract
1.00
Citrus Aurantium Dulcis (Orange) Fruit Extract
0.20
C
Brij™ O20
Oleth-20
Croda, Inc.
3.00
Citropol® H
Polycitronellol
P2 Science
1.50
Tocopherol
0.10
Phenoxyethanol
0.70
Caprylyl Glycol (and) Ethylhexylglycerin
0.50
Polysorbate 20
3.00
Tetrahexyldecyl Ascorbate
0.01
D
Citric Acid
0.25
Procedure
- Add Water, Aloe, Glycerin to the main beaker and begin heating to 65ºC while mixing.
- Slowly add the rest of Phase A.
- Once at 65ºC, cover and mix at high speed for 30 minutes.
- 4.While Phase A is heating, premix Phases B and C.
- Phase B: add water to suitable beaker and mix at a sufficient speed to produce a vortex. Slowly add the rest of Phase B while mixing.
- Phase C: combine Oleth-20, Citropol® H, and Polysorbate 20 in a small beaker, the heat to 45ºC to melt the Oleth-20. Once the Oleth is melted, remove from heat and add the rest of Phase C. Mix well by hand.
- After 30 minutes mixing at 65ºC, remove the main beaker from heat to begin cooling to 40ºC while mixing. If desired, submerge in water & ice bath to decrease cooling time.
- Once cooled to 40ºC or below, slowly add Phase B while mixing. Continue mixing until incorporated.
- Slowly add Phase C while mixing.
- Add Phase D and mix well.
- Pour into suitable component and enjoy!

The information in this document is intended to demonstrate the possible technical applications and uses of P2 Science, Inc’s cosmetic ingredient(s) for informational purposes only. Any recommendations or suggestions are made without guarantee or warrantee in each country. This is not a license under any intellectual property right of any entity or a recommendation or authorization to action that infringes any intellectual property right. P2 Science, Inc shall not be held liable for any direct or indirect damages arising out of or in connection with the accuracy, completeness, adequacy, use, or reliance upon information provided herein. It is the customer’s responsibility to determine the full safety, suitability, and regulatory compliance for their own use of the product demonstrated herein.